This free PFMEA template is an Excel workbook laid out to the AIAG-VDA FMEA Handbook (2019): 30 columns in the order of the 7 steps, from the process step to the control plan reference, with rating scales on their own sheet and an Action Priority formula that fills in as you rate. Below: what goes in each column, 6 filled rows from a stamping line and how each row reaches the control plan. For the full walk-through, see the PFMEA example.
Get the PFMEA template
A free Excel file: the AIAG-VDA 7-step form, rows linked to your process steps, Action Priority worked out for you and a rating guide.
Next to it: the control plan template and the design twin, the DFMEA template.
What Is in the PFMEA Template
- FMEA sheet: the planning header (step 1) and 30 columns grouped as Structure, Function, Failure, Risk and Optimization, ending in a control plan reference.
- Action Priority formula: enter Severity, Occurrence and Detection and the AP cell shows High, Medium or Low from the AIAG-VDA table.
- Rating Scales sheet: the 1 to 10 Severity, Occurrence and Detection criteria for process FMEAs.
- How to use sheet: what each column is for, in the order you fill it in.
PFMEA Template Preview
The FMEA sheet with 2 rows filled in (a shortened view: the workbook has every column listed in the next section).
| Station | Process step | Failure mode | Potential cause (6M) | S | O | D | AP |
|---|---|---|---|---|---|---|---|
| Op 30 | Progressive stamping (form) | Crack at bend radius | Material: coil hardness above spec | 10 | 4 | 5 | High |
| Op 30 | Progressive stamping (form) | Crack at bend radius | Machine: die radius worn | 10 | 3 | 5 | Medium |
PFMEA Format: Column by Column
The AIAG-VDA PFMEA format follows the 7 steps from left to right. What to write in each group of the template:
| Step | Columns in the template | What to write |
|---|---|---|
| 1. Planning and preparation | Project name, team, date, revision, scope (header) | The process, the part and the boundary of the analysis |
| 2. Structure analysis | Process area, Station, Process step | The process flow, 1 row group per step, matching the process flow diagram |
| 3. Function analysis | Process function, Affected product characteristic, Process characteristic, Specification or tolerance | What the step must achieve and the characteristic it controls |
| 4. Failure analysis | Failure mode, Effect on your site, Effect on ship-to site, End user effect, Potential cause, 6M cause category | How the step fails, the effect at each level and the cause by man, machine, material, method, measurement or environment |
| 5. Risk analysis | Prevention controls, Detection controls, Special characteristic, Severity, Occurrence, Detection, Action Priority | The controls in place today, their ratings and the AP the formula returns |
| 6. Optimization | Recommended actions, Responsible person, Target date, Status, Action taken, Revised S, O, D and AP | Actions for High and Medium AP rows, then the ratings after the action |
| 7. Results documentation | Control plan reference | The control plan line that carries each control |
PFMEA Example: 6 Filled Rows
An example, not a reference: 6 rows from the B-pillar bracket stamping PFMEA in our PFMEA example, which also shows the controls and actions for each row.
| Op | Failure mode | End user effect | Potential cause (4M) | S | O | D | AP |
|---|---|---|---|---|---|---|---|
| 10 | Wrong material grade received | Part fails crash test | Material: supplier ships wrong grade | 10 | 2 | 3 | Low |
| 30 | Crack at bend radius | Crash performance failure | Material: coil hardness above spec | 10 | 4 | 5 | High |
| 30 | Crack at bend radius | Crash performance failure | Machine: die radius worn | 10 | 3 | 5 | Medium |
| 40 | Hole position out of tolerance | Bolt pattern misalignment at the OEM | Machine: locator pin wear | 7 | 4 | 3 | Medium |
| 50 | Weld strength below 15 kN | OEM line stop, field joint failure | Machine: electrode cap worn | 8 | 5 | 6 | Medium |
| 70 | Out-of-spec part shipped | OEM assembly issue, sort and rework | Man: inspector misses defect under fatigue | 7 | 3 | 5 | Medium |
From the PFMEA to the Control Plan
Every detection control in the PFMEA needs a control plan line: what is checked, how, how often and what happens when it fails. For the High row above (crack at the bend radius from coil hardness), the control plan gets inline crack detection on 100% of parts with an automatic reject. Fill the control plan reference column with that line’s number. The free control plan template has the matching columns.
Common PFMEA Template Mistakes
- Process steps that do not match the process flow. The PFMEA, the process flow diagram and the control plan should use the same step numbers.
- Severity not taken from the DFMEA. When the effect is the same, the PFMEA severity should match the design severity.
- “Operator error” as a cause. Name what lets the error happen: a missing fixture, no error-proofing, an unclear instruction.
- Controls missing from the control plan. A detection control that is not on the control plan is not done on the line.
- No feedback from the line. 8Ds, complaints and a Reverse FMEA on the shop floor should change the ratings.
When an Excel PFMEA Stops Working
A template works for 1 line. Across sites it breaks down: every site edits its own copy and a fix made in 1 never reaches the others. Tacit AI is PFMEA software that builds the PFMEA and control plan from your process flow, DFMEA and 8Ds, rated to AIAG-VDA Action Priority, with every row traced to its source. A Reverse FMEA walkthrough turns each gap found at a station into a PFMEA suggestion, and derived PFMEAs stay in sync with their master. Your engineers approve every change.

Supplying an OEM? See our automotive FMEA software, or book a working session and bring 1 process.
Frequently Asked Questions
What is a PFMEA template?
A PFMEA template is a worksheet with the columns a Process FMEA needs: process steps, functions, characteristics, failure modes, effects, causes, controls, Severity, Occurrence, Detection, the actions and the control plan reference. This one follows the AIAG-VDA FMEA Handbook (2019) and works out Action Priority for you.
Is this PFMEA template free?
Yes. The Excel workbook is free to download and use on your own processes, including the rating scales and the Action Priority sheet.
What is the PFMEA format in AIAG-VDA?
The AIAG-VDA format follows the 7 steps from left to right: planning, structure, function, failure, risk, optimization and results documentation. In a PFMEA the structure is the process flow, and the causes are grouped by 4M or 6M.
How does the PFMEA link to the control plan?
Each prevention and detection control in the PFMEA becomes a control plan line with the characteristic, method, sample size, frequency and reaction plan. The template’s last column holds the control plan reference for each row.
What is the difference between a PFMEA and a DFMEA template?
A PFMEA template analyzes the manufacturing process step by step. A DFMEA template analyzes the product design component by component. See the DFMEA template.
Can I use an Excel PFMEA for PPAP?
Many customers accept an AIAG-VDA PFMEA in Excel when it matches the process flow and the control plan. Some OEM customer-specific requirements ask for FMEA software, foundation FMEAs and Reverse FMEA records, which an Excel file cannot show on its own.